PSR-M-EM6-HTL2-SC - Extension module

Safe extension module for monitoring zero-speed, speed, direction of rotation, monitoring of 2axes, NPN/PNP proximity switch, 2xHTL encoder, TBUS interface, up to SIL3, Cat.4/PLe, pluggable screw terminal block, TBUS connector included
Cod. Articolo: 1105016 copia - copy
Cod. Fornitore: 1105016 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Safety device
Application: Over-speed safety relay
Zero-speed safety relay
Monitoring the direction of rotation
Insulation characteristics
Protection class: III
Times
Response time: see user manual
Restart time: min. 5 s (Boot time)
max. 10 s (Boot time)
Electrical propertiesMaximum power dissipation for nominal condition: 3.22 W (UBÂ=Â28.8ÂV, IN1Â=ÂIN2Â=Â50ÂmA, UENCÂ=Â30ÂV)
Nominal operating mode: 100% operating factor
Interfaces: DIN rail TBUS for connection to the master module, supplied as standard
Encoder
Proximity switches
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VÂAC
Rated surge voltage/insulation: Basic insulation 4ÂkV between 24ÂV power supply and I/Os to the housing
Supply
Designation: A1/A2
Rated control circuit supply voltage US: 19.2 VÂDC ... 28.8 VÂDC
24 VÂDC -20Â%Â/Â+20Â% (provide external protection, typically 1ÂA)
Rated control supply current IS: typ. 50 mA
Power consumption at US: typ. 1.2 W
Inrush current: 3.5 A (ΔtÂ=Â1Âms at Us)
Filter time: typ. 20 ms (in the event of voltage dips at Us)
Protective circuit: Serial protection against polarity reversal
Suppressor diode
Input dataMeasurement
Input name: Proximity switch inputs
Description of the input: NPN / PNP (3- or 4-wire)
Number of inputs: 2
Input voltage range "0" signal: 0 VÂDC ... 5 VÂDC (NPN)
16 VÂDC ... 28.8 VÂDC (PNP)
Input voltage range "1" signal: 16 VÂDC ... 28.8 VÂDC (NPN)
0 VÂDC ... 5 VÂDC (PNP)
Input current range "0" signal: < 2 mA (NPN)
Precision: 5 % (in reference to the parameterized limit value)
Limit frequency: max. 5 kHz
Max. permissible overall conductor resistance: 150 Ω
Protective circuit: Suppressor diode
Current consumption: typ. 13 mA (NPN, at US)
typ. -13 mA (PNP, at Us)
max. 17 mA (NPN, at 28.8ÂVÂDC)
max. -15 mA (PNP, at 28.8ÂVÂDC)
Measurementâۉ€¹
Input name: Encoder inputs
Description of the input: HTL
IEC 61131-2 TypeÂ2
Number of inputs: 2
Precision: 5 % (in reference to the parameterized limit value)
Limit frequency: max. 300 kHz
Max. permissible overall conductor resistance: 150 Ω
HTL Signal form/signal level: 11 V ... 30 V (Duty factor trace A, B:Â50%±15%,Âphase shift trace A, B: 90°Ãƒ‚±40°)
Current consumption: typ. 12 mA (Per track for US)
Output dataDigital: Proximity switch supply (24V/0V)
Short-circuit protection: no
Nominal output voltage range: 16.7 VÂDC ... 26.3 VÂDC (USÂ-Â2,5ÂV)
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Screw connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 12
Stripping length: 7 mm
Screw thread: M3
Tightening torque: 0.5 Nm ... 0.6 Nm
SignalingStatus display: 1 x LED (green), 2 x LED (orange)
6 x LED (yellow)
Operating voltage display: 1 x green LED
Error indication: 2ÂxÂLED (red)
DimensionsWidth: 22.61 mm
Height: 112.58 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide PA non-reinforced
CharacteristicsSafety data: ENÂISOÂ13849-1
Category: 4
Performance level (PL): e
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 3
Safety data: ENÂIEC 62061
Safety Integrity Level (SIL): 3
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -10°C ... 55°C (observe derating)
Ambient temperature (storage/transport): -20°C ... 85°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 95 % (non-condensing)
Max. permissible relative humidity (operation): 95 % (non-condensing)
Shock: 10g for ΔtÂ=Â16Âms (continuous shock, 1000 shocks in each space direction)
Vibration (operation): 10ÂHzÂ...Â150ÂHz, 2g
ApprovalsCE
Identification: CE-compliant
MountingMounting type: DIN rail mounting
Assembly instructions: Observe derating
Mounting position: vertical or horizontal
Connection method: Screw connection
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00901.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Certification_00224.pdf

Certification_00318.pdf

Data_sheet_00651.pdf

Manual_00057.pdf

Manual_00058.pdf

Manufacturer_declaration_01351.pdf

Manufacturer_declaration_02194.pdf

Manufacturer_declaration_05475.pdf

Package_slip_01954.pdf