Automazione Industriale

Meccatroinca

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1125988
PHOENIX CONTACT 1125988
PHOENIX CONTACTNon disponibile

PLC-RPT-120UC/21/SO46 - Relay Module

PLC-INTERFACE for protection against interference currents/voltages on the control side. Consisting of PLC-BPT-120UC/21/SO46 basic terminal block with Push-in connection and plug-in miniature relay with power contact up to 6A, 1changeover contact, 120VAC input voltage
Cod. Articolo: 1125988 copia - copy
Cod. Fornitore: 1125988 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
NotesGeneral: Separating plate PLC-ATP must be installed for voltages larger than 250ÂV (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500....
The PLC-ATP separating plate should be installed for safe isolation between adjacent modules
The PLC-ATP separating plate is required at the start and end of every PLC terminal strip.
The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.
Product propertiesProduct type: Relay Module
Product family: PLC-INTERFACE
Application: Filter to prevent interference
Operating mode: 100% operating factor
Mechanical service life: 2x 107 cycles
Insulation characteristics
Insulation: Safe isolation, reinforced insulation
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation: Safe isolation, reinforced insulation
Overvoltage category: III
Pollution degree: 3
Electrical propertiesMaximum power dissipation for nominal condition: 0.84 W
Test voltage (Winding/contact): 4 kVrms (50ÂHz, 1Âmin., winding/contact)
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VÂAC
Rated surge voltage: 6 kV
Input dataCoil side
Nominal input voltage UN: 120 VÂAC
110 VÂDC
Input voltage range: 93.6 VÂAC ... 168 VÂAC (20°C)
85.8 VÂDC ... 154 VÂDC (20°C)
Mains frequency: 50/60 Hz
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 7 mA (50ÂHz)
8 mA (60ÂHz)
Typical response time: 7 ms
Typical release time: 20 ms
Typical release voltage: 50 VÂAC
Coil voltage: 60 VÂDC
Protective circuit: Bridge rectifier
RC element
Status display: Yellow LED
Output dataSwitching
Contact switching type: 1Âchangeover contact
Type of switch contact: Single contact
Contact material: AgSnO, hard gold-plated
Maximum switching voltage: 250 V AC/DC
Minimum switching voltage: 5 V (100 mA)
Limiting continuous current: 6 A
Maximum inrush current: 10 A (4 s)
Min. switching current: 10 mA (12ÂV)
Short-circuit current: 200 A (conditional short-circuit current)
Interrupting rating (ohmic load) max.: 140 W (24ÂVÂDC)
20 W (48ÂVÂDC)
18 W (60ÂVÂDC)
23 W (110ÂVÂDC)
40 W (220ÂVÂDC)
1500 VA (250ÂVÂAC)
Switching capacity min.: 0.12 W
Output fuse: 4 A gL/gG NEOZED
Switching capacity: 2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15)
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 94 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection (Relay): RT III (Relay)
Degree of protection (Relay base): IP20 (Relay base)
Degree of protection (Installation location): IP54 (Installation location)
Ambient temperature (operation): -40°C ... 55°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
Shipbuilding approval
Certificate: TAE0000196
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
ENÂ60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_00240.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01883.pdf

Manufacturer_declaration_03375.pdf

Manufacturer_declaration_03376.pdf

Manufacturer_declaration_03596.pdf

Product_information_00033.pdf

Product_information_00080.pdf

Technical_drawing_09023.pdf