Automazione Industriale

Meccatroinca

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1291615
PHOENIX CONTACTNon disponibile

ELR DCR-PT-24DC-3 - Reversing load relay

Electronic reversing load relay, for controlling DC motors, with LED display and protective circuit, output: 24 V DC/3 A with a switch-over time of 5 ms
Cod. Articolo: 1291615 copia - copy
Cod. Fornitore: 1291615 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Descrizione
Caratteristiche Tecniche
Product propertiesProduct type: Solid-state contactor
Product family: CONTACTRON
Operating mode: 100% operating factor
MTTF: 244 Years (ï…Å= 20 °C )
Data management status
Article revision: 03
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation: Basic insulation
Electrical propertiesNumber of phases: 1
Switching frequency: ≤ 10 Hz
Mains type: 1-phase
Test voltage (Input/output): 2.5 kVrms (50 Hz, 60 s)
Insulation characteristics
Rated insulation voltage: 50 V
Rated surge voltage: 800 V
Overvoltage category: III
Degree of pollution: 2
Air clearances and creepage distances between the power circuits: Basic insulation
Input dataInput name: DC input
Rated control circuit supply voltage US: 24 V DC
Control supply voltage range: 13 V DC ... 30 V DC
Protective circuit: Surge protection
Control
Input name: Control input right/left
Current consumption: 3 mA
Rated actuating voltage UC: 24 V DC
Triggering voltage range: 19.2 V DC ... 28.8 V DC
Rated actuating current IC: < 2 mA
Protective circuit: Reverse polarity protection
Surge protection
Surge voltage protection: > 33 V DC
Switchover time RL/LL (turn-on time): 5 ms
Output dataDC output
Rated operating voltage Ue: 24 V DC
Operating voltage range: 11 V DC ... 30 V DC
Rated operating current (DC-13 / Load output): 3 A (see to derating)
Quiescent current: ï‚» 14 mA
Short-circuit current: 100 A
Protective circuit: Reverse polarity protection
Surge protection
Surge voltage protection: > 33 V DC
Current limitation at short-circuits: 75 A
Connection dataControl circuits
Connection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
Conductor cross section AWG: 26 ... 14
Load circuit
Connection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
Conductor cross section AWG: 26 ... 14
SignalingStatus display: LED (yellow)
Operating voltage display: Green LED
Error indication: Red LED
DimensionsWidth: 12.5 mm
Height: 107 mm
Depth: 114.5 mm
Material specificationsColor: gray (RAL 7042)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25 °C ... 70 °C
Ambient temperature (storage/transport): -40 °C ... 80 °C
Altitude: ≤ 2000 m
ApprovalsUKCA
Certificate: UKCA-compliant
UL approval
Certificate: NKCR.E172140
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: EN 60947-5-1
MountingMounting type: DIN rail mounting
Assembly note: alignable, for spacing see derating
Mounting position: vertical (horizontal DIN rail, motor output below)
Descrizione
ELR DCR-PT-24DC-3 Rele inversione di marcia