PHOENIX CONTACT 1416570
PHOENIX CONTACTNon disponibile

VS-OE-OE-936-100,0 - Data cable

Data cable, PROFINET CAT5 (100 Mbps), 4-position halogen-free, shielded, free cable end, on free cable end, cable length: 100 m
Cod. Articolo: 1416570 copia - copy
Cod. Fornitore: 1416570 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Data cable by the meter
Sensor type: PROFINET
Number of positions: 4
Application: Railway applications
Shielded: yes
Electrical propertiesTransmission medium: Copper
InterfacesSignal type/category: PROFINET CAT5 (IEC 11801:2002), 100 Mbps
ConnectorConnection 1
Type: free cable end
Connection 2
Type: free cable end
Cable/lineCable length: 100 m
PROFINET RADOX
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/35eeeb11fbacdc4187dc972d16fa1966/-S204x204-FJPG
Cable weight: 81 g/m
Number of positions: 4
Shielded: yes
Cable type: PROFINET RADOX® railway application CAT5 reinforcedÂ[936]
Conductor structure: 1x4xAWG22/7, SF/TQ
Signal speed: 66 c
Conductor structure signal line: 7x 0.25 mm
AWG signal line: 22
Conductor cross section: 4x 0.34 mm²
Wire diameter incl. insulation: 1.95 mm
External cable diameter: 7.25 mm ±0.3Âmm
Outer sheath, material: PE-X
External sheath, color: black RALÂ9005
Conductor material: silver-plated Cu litz wires
Material wire insulation: PE-X
Single wire, color: white-blue, orange-yellow
Thickness, outer sheath: ≥ 0.8 mm
Overall twist: Star quad
Optical shield covering: 100 %
Max. conductor resistance: ≤ 54.4 Ω/km
Coupling resistance: 200.00 mΩ/m (f ≤ 30 MHz)
Wave impedance: 100 Ω ±5ÂΩ (f = 100 MHz)
Working capacitance: ≤ 65 pF (Line-line)
≤ 100 pF (Line-shield)
Nominal voltage, cable: 300 VÂAC
Test voltage: 2000 VÂAC (50 Hz, 5 minutes)
Minimum bending radius, fixed installation: 6 x D
Minimum bending radius, flexible installation: 10 x D
Near end crosstalk attenuation (NEXT): 80 dB (with 1 MHz)
76 dB (at 4 МHz)
67 dB (at 10 MHz)
60 dB (at 31.5ÂМHz)
56 dB (at 62.5ÂМHz)
53 dB (at 100 MHz)
Return attenuation (RL): 35 dB (at 4 МHz)
35 dB (at 10 MHz)
35 dB (at 31.5ÂМHz)
33 dB (at 62.5ÂМHz)
33 dB (at 100 MHz)
Remote crosstalk attenuation (FEXT): 80 dB (with 1 MHz)
70 dB (at 4 МHz)
65 dB (at 10 MHz)
58 dB (at 31.5ÂМHz)
59 dB (at 62.5ÂМHz)
67 dB (at 100 MHz)
Shield attenuation: 2 dB (with 1 MHz)
4 dB (at 4 МHz)
6.5 dB (at 10 MHz)
10.5 dB (at 31.5ÂМHz)
14 dB (at 62.5ÂМHz)
18 dB (at 100 MHz)
40 dB (30 MHz ≤ f ≤ 100 MHz)
Halogen-free: in accordance with EN 50267-2-1
Flame resistance: ENÂ60332-1-2
ENÂ50266
ENÂ60332-3-25
NFÂC32-070, 2.1
NFÂC32-070, 2.2
ULÂ1685, 12 (FT4)
in accordance with ISOÂ6722-1 5.22 (UN ECE-R 118.01)
Fume corrosiveness: ENÂ50267-2-2
Fume toxicity: BSÂ6853 B.1
ENÂ50305, 9.2
Concentration of fumes: BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Resistance to oil: according to IRM 902, 72 h at 100°C
Fire protection in rail vehicles: BSÂ6853 (Category Ia, Ib, II)
GM/RTÂ2130 (Category Ia, Ib, II)
ENÂ45545 (Risk level HL1 - HL3)
DINÂ5510 (Fire protection level 1, 2, 3, 4)
NFÂF16-101 (Category A1, A2, B)
NFÂF16-101 (Class C/F0)
NFPAÂ130
UNIÂCEIÂ11170 (Risk level LR1 - LR4)
Other resistance: Resistance to fuels according to IRM 903, 168 h at 70°C
Ambient temperature (operation): -50°C ... 90°C (cable, fixed installation)
-40°C ... 90°C (Cable, flexible installation)