Automazione Industriale

Meccatroinca

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1421947
PHOENIX CONTACTNon disponibile

SAC-5P-M12MS/2,0-PUR/M8SIFSBBK - Sensor/actuator cable

Sensor/actuator cable, 5-position, PUR halogen-free, black-gray RAL 7021, Plug straight M12, coding: A, on Socket straight M8 Snap-in, coding: B, cable length: 2 m
Cod. Articolo: 1421947 copia - copy
Cod. Fornitore: 1421947 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Sensor/actuator cable
Number of positions: 5
No. of cable outlets: 1
Shielded: no
Insulation characteristics
Overvoltage category: II
Degree of pollution: 3
Material specificationsFlammability rating according to UL 94: HB
Seal material: NBR
Material of grip body: TPU, hardly inflammable, self-extinguishing
Contact material: CuSn
Contact surface material: Ni/Au
Contact carrier material: TPU GF
Material for screw connection: Zinc die-cast, nickel-plated
Outer sheath, material: PUR
Conductor material: Bare Cu litz wires
Electrical propertiesInsulation resistance: ≥ 100 MΩ
Nominal voltage UN: 30 V AC
30 V DC
Nominal current IN: 4 A
Max. conductor resistance: 58 Ω/km
Mechanical propertiesMechanical data
Max. bending cycles: 4000000
SignalingStatus display: no
Status display present: No
ConnectorConnection 1
Type: Plug straight M12
Number of positions: 5
Coding type: A
Connection 2
Type: Socket straight M8 Snap-in
Number of positions: 5
Locking type: Snap-in
Coding type: B
Cable/lineCable length: 2 m
PUR, black, 5th conductor gray [115]
Dimensional drawing: https://caas.phoenixcontact.com/caas/v1/stable/media/9080/full/b1500?format=jpg
Cable weight: 35 kg/km
UL AWM Style: 20549 / 10493 (80 °C/300 V)
Number of positions: 5
Shielded: no
Cable type: PUR, black, 5th conductor gray [115]
Conductor structure signal line: 42x 0.10 mm
AWG signal line: 22
Conductor cross section: 5x 0.34 mm²
Wire diameter incl. insulation: 1.27 mm ±0.02 mm
External cable diameter: 5.00 mm ±0.15 mm
Outer sheath, material: PUR
External sheath, color: black-gray RAL 7021
Conductor material: Bare Cu litz wires
Material, filler: PP
Material wire insulation: PP
Single wire, color: brown, white, blue, black, gray
Thickness, insulation: ≥ 0.21 mm
Thickness, outer sheath: approx. 0.70 mm
Overall twist: 5 cores, twisted
Max. conductor resistance: ≤ 58 Ω/km
Nominal voltage, cable: ≤ 300 V
Test voltage: ≥ 3000 V
Minimum bending radius, fixed installation: 5 x D
Minimum bending radius, flexible installation: 10 x D
Smallest bending radius, fixed installation: 25 mm
Smallest bending radius, movable installation: 50 mm
Dynamic load capacity (bending): Max. bending cycles: 4000000, Bending radius: 50 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s²
Halogen-free: in accordance with DIN VDE 0472 part 815
Flame resistance: in accordance with DIN UL-Style 20549
in accordance with UL 758/1581 FT2
Resistance to oil: in accordance with DIN EN 60811-2-1
Other resistance: partly UV-resistant (in accordance with DIN EN ISO 4892-2-A)
hydrolysis and microbe resistant
Resistant to salt water
Low adhesion
abrasion-resistant
Special properties: Flexible cable conduit capable
Silicone-free
Free of substances which would hinder coating with paint or varnish
flexible
Ambient temperature (operation): -40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (Cable, flexible installation)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP65
IP67
Ambient temperature (operation): -25 °C ... 90 °C (Plug / socket)
-40 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (Cable, flexible installation)
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Manufacturer_declaration_00238.pdf

Manufacturer_declaration_02468.pdf

Manufacturer_declaration_05518.pdf