PLC-RPT-110UC/21/RW - Relay Module

PLC-INTERFACE for railway applications, consisting of basic terminal block with Push-in connection and plug-in miniature relay with power contact, range: 0.7 x UN to 1.25 x UN, temperature class TX: -40°C to +70°C, 1 changeover contact, input voltage 110 V DC
Cod. Articolo: 2900320 copia - copy
Cod. Fornitore: 2900320 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Relay Module
Product family: PLC-INTERFACE
Installation location: Attached to the vehicle body
Application: Railway applications
Operating mode: 100% operating factor
Mechanical service life: approx. 2x 107 cycles
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.22 W
Test voltage (Winding/contact): 4 kVrms (50ÂHz, 1Âmin., winding/contact)
Rated insulation voltage: 250 VÂAC
Rated surge voltage: 6 kV
Input dataCoil side
Nominal input voltage UN: 110 VÂDC
Input voltage range: 77 VÂDC ... 137.5 VÂDC
Input voltage range in reference to UN: 0.7 ... 1.25
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 2 mA
Typical response time: 4 ms
Typical release time: 4 ms
Coil voltage: 60 VÂDC
Protective circuit: Surge protection; Freewheeling diode
RCZ filter
Wide-range electronics
Operating voltage display: Yellow LED
Output dataSwitching
Contact switching type: 1Âchangeover contact
Type of switch contact: Single contact
Contact material: AgSnO
Maximum switching voltage: 250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250ÂV (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Minimum switching voltage: 5 V (100 mA)
Limiting continuous current: 6 A
Maximum inrush current: 10 A (4 s)
Min. switching current: 10 mA (12ÂV)
Short-circuit current: 200 A (conditional short-circuit current)
Interrupting rating (ohmic load) max.: 140 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
1500 VA (for 250 V AC)
Output fuse: 4 A gL/gG NEOZED
Switching capacity: 1 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15)
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 94 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection (Relay): RT III (Relay)
Degree of protection (Relay base): IP20 (Relay base)
Ambient temperature (operation): -40°C ... 70°C (Temperature class TX)
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
Shipbuilding approval
Certificate: TAE0000196
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
ENÂ60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
Standards and regulationsStandards/regulations: IEC 60947-5-1
ENÂ50155 (VDEÂ0115 part 200)
ENÂ61373
ENÂ50121
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00002.pdf

Application_note_00006.pdf

Application_note_00146.pdf

Approvals_00240.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01883.pdf

Manufacturer_declaration_01841.pdf

Manufacturer_declaration_03375.pdf

Manufacturer_declaration_03376.pdf

Manufacturer_declaration_03596.pdf

Manufacturer_declaration_15503.pdf

Package_slip_01741.pdf

Product_information_00015.pdf

Product_information_00033.pdf

Product_information_00532.pdf

Technical_drawing_39346.pdf