PLC-OPT- 24DC/TTL - Solid-state relay module

PLC-INTERFACE for TTL signal, consisting of PLC-O.../TTL basic terminal block with push-in connection and integrated solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 24 V DC, output: TTL (5 V DC)
Cod. Articolo: 2900363 copia - copy
Cod. Fornitore: 2900363 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Solid-state relay module
Product family: PLC-INTERFACE
Application: TTL signal at output
Operating mode: 100% operating factor
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.08 W
Test voltage (Input/output): 2.5 kVrms (50ÂHz, 1Âmin., input/output)
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VÂDC
Rated surge voltage: 4 kV
Input dataRated actuating voltage UC: 24 VÂDC
Voltage range with reference to UC: 0.8 ... 1.2
Rated actuating current IC: 3.4 mA
Switching threshold "0" signal in reference to UN: < 0.4
Switching threshold "1" signal in reference to UN: > 0.8
Typical input current at UN: 3.4 mA
Typical response time: 35 µs
Typical turn-off time: 35 µs
Operating voltage display: Yellow LED
Protective circuit: Reverse polarity protection; Parallel polarity protection diode
Surge protection
Surge voltage protection: > 33 V
Transmission frequency: 1 kHz
Output dataDesignation: Output data
Contact switching type: 1 N/O contact
Design of digital output: electronic
Contact connection type: Signal contact
Rated control circuit supply voltage US: 5 VÂDC
Voltage range with reference to US: 0.9 ... 1.2
Output voltage range: 4.5 VÂDC ... 6 VÂDC
Limiting continuous current: 50 mA (a TTL load (Fan out = 1))
Fan out: 1
Surge voltage protection: > 8 V
Voltage drop at max. limiting continuous current: < 80 mV
Output circuit: 3-conductor, ground-referenced
Protective circuit: Reverse polarity protection; Parallel polarity protection diode
Surge protection
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 86 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsCorrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
ENÂ60068-2-60
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01883.pdf

Manufacturer_declaration_01205.pdf

Manufacturer_declaration_01848.pdf

Manufacturer_declaration_03448.pdf

Manufacturer_declaration_03449.pdf

Manufacturer_declaration_03605.pdf

Manufacturer_declaration_15539.pdf

Package_slip_01741.pdf

Product_information_00033.pdf

Product_information_00842.pdf

Technical_drawing_39382.pdf