TRIO-PS/1AC/5DC/10 - Power supply unit

Primary-switched TRIO POWER power supply for DIN rail mounting, input: 1-phase, output: 5VDC/10A
Cod. Articolo: 2902646 copia - copy
Cod. Fornitore: 2902646 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Input dataNominal input voltage range: 100 VÂAC ... 240 VÂAC
Input voltage range: 85 VÂAC ... 264 VÂAC (Derating < 90 V AC: 2.5 %/K)
Derating: < 90 VÂAC (2.5Â%/V)
Input voltage range AC: 85 VÂAC ... 264 VÂAC (Derating < 90 V AC: 2.5 %/K)
Electric strength, max.: 300 VÂAC
Voltage type of supply voltage: AC
Inrush current: < 30 A
Inrush current integral (I2t): < 1.9 A2s
AC frequency range: 45 Hz ... 65 Hz
Mains buffering time: > 40 ms (120ÂVÂAC)
> 180 ms (230 V AC)
Current consumption: 1 A (120ÂVÂAC)
0.5 A (230 V AC)
Nominal power consumption: 131.4 VA
Protective circuit: Transient surge protection; Varistor
Power factor (cos phi): 0.48
Typical response time: < 1 s
Permissible backup fuse: B6 B10 B16
Recommended breaker for input protection: 6 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE: < 3.5 mA
Output dataEfficiency: > 80 % (230 V AC)
Output characteristic: U/I
Nominal output voltage: 5 VÂDC ±1Â%
Setting range of the output voltage (USet): 4.5 VÂDC ... 6 VÂDC (> 12 VÂDC, constant capacity restricted)
Nominal output current (IN): 10 A (-25°CÂ...Â55°C)
Derating: 55°C ... 70°C (2.5%/K)
Feedback voltage resistance: approx. 9 VÂDC
Protection against overvoltage at the output (OVP): < 9 VÂDC
Max. capacitive load: unlimited
Active current limitation: Approx. 12 A (in the event of a short-circuit)
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple: < 60 mVPP
Output power: 50 W
Peak switching voltages nominal load: < 70 mVPP
Maximum no-load power dissipation: 1.5 W
Power loss nominal load max.: 13.5 W
Rise time: < 2 ms (UOUT (10 % ... 90 %))
Connection in parallel: yes, for redundancy and increased capacity
Connection in series: yes
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 14
Stripping length: 9 mm
Screw thread: M2,5
Tightening torque, min: 0.4 Nm
Tightening torque max: 0.5 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 14
Stripping length: 9 mm
Screw thread: M2,5
Tightening torque, min: 0.4 Nm
Tightening torque max: 0.5 Nm
SignalingTypes of signaling: LED
Signal output
Status display: "DC OK" LED green
Note on status display: UOUT < 0.9 x UN: LED flashing
Electrical propertiesInsulation voltage input/output: 4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE: 500 VÂDC (routine test)
Insulation voltage input / PE: 2 kV AC (type test)
2 kV AC (routine test)
Product propertiesProduct type: Power supply
Product family: TRIO POWER
MTBF (IEC 61709, SN 29500): > 500000 h
Insulation characteristics
Protection class: I
Overvoltage category: III
Degree of pollution: 2
DimensionsWidth: 40 mm
Height: 130 mm
Depth: 115 mm
Installation dimensions
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 50 mm / 50 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: horizontally 0Âmm, vertically 50Âmm
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: No
Material specificationsHousing material: Metal
Type of housing: Steel sheet, zinc-plated
Side element version: Aluminum
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): ≤ 95 % (at 25°C, non-condensing)
Shock: 15g in all directions in acc. with IEC 60068-2-27
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulationsRail applications: ENÂ50121-4
Standard âۉ€œ Electronic equipment for use in electrical power installations and their assembly into electrical power installations: ENÂ50178/VDEÂ0160 (PELV)
Standard âۉ€œ Limitation of mains harmonic currents: ENÂ61000-3-2
Standard - Electrical safety: ENÂ60950-1/VDEÂ0805 (SELV)
ENÂ61558-2-17
Standard âۉ€œ Protection against shock currents, basic requirements for protective separation in electrical equipment: ENÂ50178
Standard âۉ€œ Safety extra-low voltage: ENÂ60950-1 (SELV)
ENÂ60204 (PELV)
Standard - Safe isolation: DINÂVDEÂ0100-410
Standard - Safety of transformers: ENÂ61558-2-17
ApprovalsUL approvals: UL/C-UL listed ULÂ508
UL/C-UL Recognized ULÂ60950-1
Conformity/Approvals
SIL in accordance with IEC 61508: 0
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission: ENÂ61000-6-3
ENÂ61000-6-4
EMC requirements for noise immunity: ENÂ61000-6-1
ENÂ61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations: ENÂ61000-4-2
Housing: Level 3
Electrostatic dischargeâۉ€¹
Contact discharge: 6 kV
Discharge in air: 8 kV
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: ENÂ61000-4-3
Electromagnetic HF fieldâۉ€¹
Frequency range: 80 MHz ... 3 GHz
Test field strength: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: ENÂ61000-4-4
Fast transients (burst)âۉ€¹
Input: 4 kV (level 4 - asymmetrical: conductor to ground)
Output: 2 kV (level 3 - asymmetrical: conductor to ground)
Comments: Criterion B
Surge voltage load (surge)
Standards/regulations: ENÂ61000-4-5
Conducted interference
Standards/regulations: ENÂ61000-4-6
Conducted interferenceâۉ€¹
Input/Output: Level 3 - asymmetrical
Frequency range: 10 kHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V
Voltage dips
Standards/regulations: ENÂ61000-4-11
Emitted interference
Standards/regulations: ENÂ61000-6-3
Radio interference voltage in acc. with EN 55011: ENÂ55011 (ENÂ55022) ClassÂB, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential