PLC-OSC-LPE-24DC/48DC/100 - Timer module

1-channel pulse expansion module, input: 24 V DC, output: 3 - 48 V DC/100 mA, supply: 24 V DC, screw connection
Cod. Articolo: 2903171 copia - copy
Cod. Fornitore: 2903171 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Solid-state relay module
Product family: PLC-INTERFACE
Application: Pulse stretching
Operating mode: 100% operating factor
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation: Basic insulation
Overvoltage category: II
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.07 W
Test voltage (Input/output): 2.5 kVrms (50ÂHz, 1Âmin., input/output)
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 50 VÂDC
Rated surge voltage: 0.5 kV
Input dataRated control circuit supply voltage US: 24 VÂDC
Voltage range with reference to US: 0.8 ... 1.2
Rated control supply current IS: 13 mA (Input low, output low)
19 mA (Input high, output high)
Rated actuating voltage UC: 24 VÂDC
Rated actuating current IC: 3 mA
Input voltage range: 19.2 VÂDC ... 28.8 VÂDC
"0" signal switching threshold in reference to UC: < 0.4
"1" signal switching threshold in reference to UC: > 0.8
Status display: Yellow LED
Operating voltage display: Green LED
Protective circuit: Reverse polarity protection
Surge protection
Surge voltage protection: > 33 VÂDC
Output dataContact switching type: 1 N/O contact
Design of digital output: electronic
Output voltage range: 3 VÂDC ... 48 VÂDC
Limiting continuous current: 100 mA
Surge voltage protection: > 54 VÂDC
Voltage drop at max. limiting continuous current: < 1 VÂDC
Output circuit: 3-conductor, ground-referenced
Protective circuit: Reverse polarity protection
Surge protection
Free running
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing))
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 86 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 60°C
Ambient temperature (storage/transport): -25°C ... 75°C
ApprovalsCorrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
ENÂ60068-2-60
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_01883.pdf

Manufacturer_declaration_04119.pdf

Manufacturer_declaration_04120.pdf

Manufacturer_declaration_15787.pdf

Package_slip_01751.pdf

Product_information_00033.pdf

Product_information_00585.pdf

Technical_drawing_39719.pdf