PLC-OPT- 24DC/230AC/2.4/ACT - Solid-state relay module

PLC-INTERFACE for output functions, consisting of PLC-BPT.../ACT basic terminal block with push-in connection and integrated miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 24 V DC, output: 24 - 253 V AC/2.4 A
Cod. Articolo: 2904632 copia - copy
Cod. Fornitore: 2904632 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Solid-state relay module
Product family: PLC-INTERFACE
Application: Output function
Operating mode: 100% operating factor
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.19 W
Test voltage (Input/output): 2.5 kV (50ÂHz, 1Âmin., input/output)
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 260 VÂAC
Rated surge voltage: 4 kV
Input dataRated actuating voltage UC: 24 VÂDC
Voltage range with reference to UC: 0.8 ... 1.2
Rated actuating current IC: 8 mA
Input voltage range: 19.2 VÂDC ... 28.8 VÂDC
"0" signal switching threshold in reference to UC: < 0.4
"1" signal switching threshold in reference to UC: > 0.8
Typical response time: 10 ms (at UC)
Typical turn-off time: 10 ms (at UC)
Status display: Yellow LED
Protective circuit: Reverse polarity protection
Surge protection
Surge voltage protection: > 33 V
Transmission frequency: 10 Hz
Output dataDesignation: Output data
Contact switching type: 1 N/O contact
Design of digital output: electronic
Contact connection type: Power contact
Output voltage range: 24 VÂAC ... 253 VÂAC
Limiting continuous current: 2.4 A (see to derating)
Maximum inrush current: 250 A (20Âms)
Min. load current: 10 mA
Leakage current: < 3 mA
Max. load value: 340 A2s (tp = 10Âms, at 25°C)
Surge voltage protection: > 275 V
Voltage drop at max. limiting continuous current: < 1 V
Output circuit: 2-conductor, zero voltage switch
Protective circuit: RCV circuit
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 86 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsCorrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
ENÂ60068-2-60
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Application_note_00148.pdf

Approvals_01883.pdf

Manufacturer_declaration_01961.pdf

Manufacturer_declaration_04305.pdf

Manufacturer_declaration_04306.pdf

Manufacturer_declaration_04307.pdf

Manufacturer_declaration_15958.pdf

Product_information_00033.pdf

Product_information_00644.pdf

Technical_drawing_39997.pdf