PHOENIX CONTACT 2910511
PHOENIX CONTACT 2910511
PHOENIX CONTACTNon disponibile

PLC-RSC-120UC/21-21AU/MS - Relay Module

PLC-INTERFACE, consisting of a relay base and pluggable multilayer gold contact relay with manual operation, integrated status LED, Screw connection, 2 changeover contacts, Bridge rectifier, Input voltage: 120 VAC / 110 VDC
Cod. Articolo: 2910511 copia - copy
Cod. Fornitore: 2910511 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Relay Module
Product family: PLC-INTERFACE
Application: Palm switch
Operating mode: 100% operating factor
Mechanical service life: 5x 106 cycles
Insulation characteristics
Insulation: Safe isolation, reinforced insulation
Insulation characteristics: Standards/regulations
Insulation: Safe isolation, reinforced insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.54 W
Test voltage (Winding/contact): 4 kVrms (50ÂHz, 1Âmin., winding/contact)
Test voltage (Changeover contact/changeover contact): 2.5 kVrms (50ÂHz, 1Âmin., changeover contact/changeover contact)
Standards/regulations
Rated insulation voltage: 250 VÂAC
Rated surge voltage: 6 kV
Input dataCoil side
Nominal input voltage UN: 120 VÂAC
110 VÂDC
Input voltage range: 96 VÂAC ... 168 VÂAC (20°C)
93.5 VÂDC ... 154 VÂDC (20°C)
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 5 mA
Typical response time: 6 ms (110ÂVÂDC)
3 ms ... 15 ms (120ÂVÂAC)
Typical release time: 10 ms (110ÂVÂDC)
Typical release time range: 3 ms ... 15 ms (120ÂVÂAC)
Protective circuit: Bridge rectifier; Bridge rectifier
Operating voltage display: Yellow LED
Output dataSwitching
Contact switching type: 2 changeover contacts
Type of switch contact: Single contact
Contact material: AgNi, hard gold-plated
Maximum switching voltage: 30 VÂAC
36 VÂDC
Minimum switching voltage: 12 V (1ÂmA)
Limiting continuous current: 50 mA
Maximum inrush current: 50 mA
Min. switching current: 1 mA (12ÂV)
Switching: when the gold layer is destroyed
Note: the following values are applicable if a gold layer is destroyed
Maximum switching voltage: 250 V AC/DC
Minimum switching voltage: 12 V (10ÂmA)
Limiting continuous current: 6 A
Maximum inrush current: 12 A (20Âms)
Min. switching current: 10 mA (12ÂV)
Interrupting rating (ohmic load) max.: 192 W (24ÂVÂDC)
62 W (48ÂVÂDC)
42 W (60ÂVÂDC)
55 W (110ÂVÂDC)
66 W (220ÂVÂDC)
2000 VA (250ÂVÂAC)
Switching capacity: 1 A (24ÂV, DC13)
1.5 A (230 V, AC15)
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.6 Nm ... 0.8 Nm
DimensionsWidth: 14 mm
Height: 80 mm
Depth: 104 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection (Relay): RT II (Relay)
Degree of protection (Relay base): IP20 (Relay base)
Degree of protection (Installation location): ≥ IP54 (Installation location)
Ambient temperature (operation): -20°C ... 55°C
Ambient temperature (storage/transport): -20°C ... 85°C
Altitude: ≤ 2000 m
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
UL, USA
Identification: ULÂ508
ULÂ508 Recognized
UL, USA/Canada
Identification: ULÂ508
ULÂ508 Recognized
Shipbuilding approval
Certificate: TAE0000196
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
ENÂ60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
Standards and regulationsStandards/regulations
Standards/regulations: ENÂ50178
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_00240.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01883.pdf

Manufacturer_declaration_03400.pdf

Manufacturer_declaration_03401.pdf

Manufacturer_declaration_03600.pdf

Manufacturer_declaration_16523.pdf

Package_slip_01757.pdf

Product_information_00033.pdf

Product_information_00756.pdf

Technical_drawing_40984.pdf