PHOENIX CONTACT 2940061
PHOENIX CONTACT 2940061
PHOENIX CONTACTNon disponibile

EMG 22-REL/KSR-230/21/AU/SO46 - Relay Module

Plug-in relay interfaces for protection against interference on the control side, with soldered-in miniature switching relay, contacts (Au): small loads, 1 changeover contact, input voltage 230 V AC
Cod. Articolo: 2940061 copia - copy
Cod. Fornitore: 2940061 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Relay Module
Product family: EMG
Application: Filter to prevent interference
Mechanical service life: approx. 2x 107 cycles
Insulation characteristics
Insulation: Basic insulation
Insulation characteristicsâۉ€¹
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 4.14 W
Test voltage (Winding/contact): 2.5 kV AC (50ÂHz, 1Âmin., winding/contact)
Input dataCoil side
Nominal input voltage UN: 230 VÂAC
Input voltage range: 207 VÂAC ... 253 VÂAC (20°C)
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 18 mA
Typical response time: 10 ms
Typical release time: 8 ms
Protective circuit: Bridge rectifier; Bridge rectifier
Surge protection; Varistor
RC element; RC element
Operating voltage display: Yellow LED
Output dataSwitching
Contact switching type: 1Âchangeover contact
Type of switch contact: Double contact
Contact material: AgPd60, hard gold-plated
Maximum switching voltage: 30 VÂAC
36 VÂDC
Limiting continuous current: 0.5 A
Maximum inrush current: 0.2 A
Interrupting rating (ohmic load) max.: 5 W (at 24 V DC)
Switching: when the gold layer is destroyed
Note: the following values are applicable if a gold layer is destroyed
Maximum switching voltage: 125 VÂAC
150 VÂDC
Limiting continuous current: 2 A
Maximum inrush current: 2 A
Interrupting rating (ohmic load) max.: 29 W (at 24 V DC)
29 W (at 48 V DC)
29 W (at 60 V DC)
Connection dataCoil side
Connection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 4 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12
Contact side
Connection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 4 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12
DimensionsWidth: 22.5 mm
Height: 75 mm
Depth: 62.5 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -20°C ... 40°C
Ambient temperature (storage/transport): -20°C ... 70°C
Standards and regulationsStandards/regulations: IEC 60664
ENÂ50178
MountingMounting type: DIN rail mounting
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00002.pdf

Application_note_00006.pdf

Manufacturer_declaration_00624.pdf

Manufacturer_declaration_01716.pdf

Manufacturer_declaration_03523.pdf

Manufacturer_declaration_03524.pdf

Manufacturer_declaration_16674.pdf

Technical_drawing_41204.pdf