HC-M-RJ45-08-GC-F/F - Contact insert module

Contact insert module, number of positions: RJ45, type : RJ45, Socket, 48 V, 1 A, application: Data, Gender changer
Cod. Articolo: 1419886 copia - copy
Cod. Fornitore: 1419886 copia - copy
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
NotesGeneral: Use the patch cable from the accessories list.
Connectors may be operated only when there is no load/voltage.
MountingAssembly instructions: To ensure correct use, installation in housing with IP54 protection or better is required
Product propertiesProduct type: Modular contact insert
Sensor type: Ethernet
Number of positions: 8
Connection profile: RJ45
Contact numbering: 1 - 8
Application: Data
Number of module slots: 1
Type: RJ45
Series: HC-M-RJ45
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3aa450688725934fb1121e8310a20839/-S204x204-FJPG
Width: 34.2 mm
Height: 36.7 mm
Length: 14.6 mm
Mechanical characteristics
Minimum housing height: 72 mm
Electrical propertiesRated voltage (III/3): 48 V
Rated surge voltage: 0.8 kV
Rated current: 1 A
Transmission characteristics (category): CAT6A (IEC 60512-27-100:2008, TIA-568-C.2:2009)
Mechanical propertiesMechanical data
Insertion/withdrawal cycles: ≥ 500
Material specificationsFlammability rating according to UL 94: V0
Contact material: Copper alloy
Contact surface material: Au
Contact carrier material: PC
Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINÂENÂ45545-2 (Risk level HL1 - HL3)
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -40°C ... 70°C
Standards and regulationsTesting
Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINÂENÂ45545-2 (Risk level HL1 - HL3)
Download